Panther Pump


The pump is mounted on a grease reservoir along with control module, vent valve assembly and follower plate. This pump is available to suite reservoir capacity of 27 , 50 and 180kg. All hoses required for the pump station assembly include vent line hose and grease refill hose. Level indicator rod is provided for monitoring the grease level in the reservoir.

Technical Specifications :


PUMP OPERATING RATIO 10:1
MAX. GREASE OUTPUT PRESSURE 480 bar
MAX. HYDRAULIC FLUID INPUT PRESSURE 41 bar
MAX. HYDRAULIC FLUID INPUT VOLUME 11.7 lpm
HYDRAULIC FLUID CONSUMPTION RATE 0.195 ltr per cycle
MAX. FLUID TEMPERATURE 121° C
OUTPUT PER CYCLE 0.6 in3/ cycletd
MAX. FLOW RATE 499 gms/min 60 cyl.
STROKE 3 in. (76.2 mm)
HYDRAULIC INLET 3/4” npt
HYDRAULIC OUTLET 3/4” npt
LUBRICANT OUTLET 1/2” npt


Alternate Text

Hydraulic Control Module


Control module is installed on the grease reservoir and consists of Solenoid Valve, Pressure Regulating Valve & Flow Control Valve. It puts the regulated hydraulic pressure gauge and flow and pressure controls in one place for total hydraulic output control.

The Hydraulic Control Module groups all hydraulic fluid system controls in one place for convenient and efficient set-up and trouble shooting


Pressure Gauge

Pressure Gauge reports the regulated hydraulic pressure being supplied to the motor for efficient set up


Three-Way Solenoid Valve

Three-Way Solenoid Valve is continuous duty rated and has hardened precision cage and spool for long life

Alternate Text

Injectors :


FM-01 Injectors (for feed lines)


Technical Specifications :

MIN. OPERATING PRESSURE 128 bar
MAX. OPERATING PRESSURE 241 bar
OUTPUT VOLUME/ CYCLE 0.131 cc. - 1.31 cc.
RESET PRESSURE/ VENT PRESSURE 41 bar

Alternate Text

FM-10 Injectors (for bucket link points)


Technical Specifications :

MIN. OPERATING PRESSURE 69 bar
MAX. OPERATING PRESSURE 241 bar
OUTPUT VOLUME/ CYCLE 0.82 cc.- 8.2 cc.
RESET PRESSURE/ VENT PRESSURE 41 bar
Alternate Text Alternate Text

Vent Valve Assembly :


Vents/ relieves the inbuilt system pressure back into the grease reservoir.

Alternate Text




Lubrication Controller (LC-02):


Features:-

  • Compact timer mounts easily in operator’s cabin

  • Simple timing set up

  • Dual monitoring function: PSI / Timer mode

  • Display indicates pump on, pause time, alarm (fault indicators) error code

  • 24 VDC power voltage

  • Indicator lights for alarm, power on, pump mode, timer mode

Alternate Text

Pressure Switch :


Pressure Setting: 75-175 bar

Tubing and Fittings :


All Tubing and Fittings are carbon steel compression type, which are as per DIN Standards 2353

Hoses :


Hoses considered are high pressure - reputed make for main line and feed Lines